冷却塔爆破拆除起爆网路可靠性的研究
RESEARCH ON RELIABILITY OF INITIATION NETWORK FOR BLASTING DEMOLITION OF COOLING TOWERS

张立国,李守巨,董振斌
ZHANG Li guo 1; LI Shou ju 2; DONG Zhen bin 3 (1. Liaoning Technical University;

摘要(Abstract):

阜新发电厂冷却塔爆破拆除适用的起爆网路有 3种。通过用可靠性理论对这三种起爆网路的可靠性进行计算和分析 ,选择了可靠度最高的导爆索导爆管雷管起爆网路 ,并在实际工程中加以应用。爆破结果表明 ,这种起爆网路不仅安全性好、实用性强 ,而且具有很高的可靠性
There are three kinds of initiation network suitable to blasting demolition of cooling towers in Fuxin Power Plant. By calculation and analysis on the reliability of these networks based on the reliability theory, the highly reliable initiation network combined Nonel detonator with detonating cord is selected and used in the demolition blasting of cooling towers. The results of blasting have shown that this initiation network is not only good in safety and applicability, but high in reliability.

关键词(KeyWords): 冷却塔;拆除爆破;起爆网路;可靠性
Cooling tower; Demolition blasting; Initiation network; Reliability